• Adult audiometry testing in sound booth with AD629 from Interacoustics

    The AD629

    The AD629 presents a new concept we like to call 'hybrid', because it combines the best of past, present and future in a compact and classic design.

    Explore AD629

The first ‘true’ hybrid audiometer

The ergonomic design of the AD629 is exceptional with an articulating, high resolution color display that presents crystal clear images for easy to read audiograms.

The power of the internal processor provides PC-like functionality without the PC! Upload multiple patient data into the AD629 before taking it on the road, then store test results to each specific client and download the information when you get back to the office to the database program of your choice.

  • 5.7" adjustable high resolution display
  • Internal storage for 500 patients/50,000 test sessions
  • Direct printouts
  • Integrated pre-recorded speech options
  • High frequency option (up to 20 kHz)

The diagnostic test battery

AD629e provides all the necessary air, bone and masking features required for basic or advanced diagnostic and clinical use. The built-in high resolution color display offers dedicated test screens as well as many display and test options.

Tone audiometry

  • Air conduction (HL, MCL & UCL)
  • Bone conduction
  • Pure Tone Stenger
  • PTA and/or CPT calculation
  • Define special audiometry symbols
  • Easily switch to 1,2 or 5dB steps
  • Display masking information
  • Speech banana

Speech audiometry

  • Graph or table mode
  • Prerecorded speech material
  • Live Voice, CD/MP3 or Wavefile
  • SRT, Word Recognition, MCL, UCL
  • Recorded Word Recognition Scoring
  • Binaural speech for CAPD applications
  • Speech Stenger

Functional design

AD629e provides all the necessary air, bone and masking features required for basic or advanced diagnostic and clinical use. The built-in high resolution color display offers dedicated test screens as well as many display and test options. Several display choices are available to customize the readout to your personal preference. The familiar keypad design will enable you to acclimate quickly without losing efficiency or speed.
Hover buttons to see a select list of AD629 functions
AD629 Diagnostic audiometer

Talk back Speaker

For speech feedback from the patient in the test cabin.

Microphone

For live voice speech and talk forward instruction to the patient in the test cabin.

Function Keys

These keys are context sensitive and depend on the selected test screen. Will be further explained in the sections describing the individual tests.

Setup / Tests

The common setting menu can be accessed for more specific tests and changes to general settings can be made. This is also where the special tests are accessed: Auto tests (HW, Békésy), MHA, SISI.

Tone Switch / Enter

Used for tone presentation where the “Tone” light will show. Can also be used as “Enter” (selection) button.

HL db Channel 1

This allows for the adjusting of the intensity in channel 1.

Masking Channel 2

Adjust the intensity level in channel 2 or masking levels when masking is used.
  • Talk back Speaker

    For speech feedback from the patient in the test cabin.
  • Microphone

    For live voice speech and talk forward instruction to the patient in the test cabin.
  • Function Keys

    These keys are context sensitive and depend on the selected test screen. Will be further explained in the sections describing the individual tests.
  • Setup / Tests

    The common setting menu can be accessed for more specific tests and changes to general settings can be made. This is also where the special tests are accessed: Auto tests (HW, Békésy), MHA, SISI.
  • Tone Switch / Enter

    Used for tone presentation where the “Tone” light will show. Can also be used as “Enter” (selection) button.
  • HL db Channel 1

    This allows for the adjusting of the intensity in channel 1.
  • Masking Channel 2

    Adjust the intensity level in channel 2 or masking levels when masking is used.

Other available tests

Define multiple user test protocols on the fly. Makes it easy and convenient for several users to share the same instrument in a clinic without having to change settings every day. Saves time and creates a optimal workflow.
  • Master Hearing Aid
  • SISI
  • Auto HL (Modified Hughson-Westlake)
  • ABLB
  • Bekesy
  • High Frequency to 20,000 Hz (optional)
  • Built-in Wavefiles (optional)
  • QuickSinTM (optional)

Hybrid products lets you choose your preferred workflow with standalone and PC audiometry operation
B71 - Compatible with all headbands as well as high-quality cables. The industrial standard of audiometric bone conduction testing. Visit RadioEar to learn more about the bone transducers.
Features and/or functions may not be available for all countries or all areas and product specifications are subject to change without prior notification.

Find ways to buy our products: Visit an Interacoustics sales office, call 45-6371-3555, or find a distributor.